Robust Optimization of Dose-Volume Metrics for Prostate HDR-Brachytherapy Incorporating Target and OAR Volume Delineation Uncertainties
Published Online:2 Jan 2019https://doi.org/10.1287/ijoc.2018.0815
References
- (2015) Dwell time modulation restrictions do not necessarily improve treatment plan quality for prostate HDR brachytherapy. Phys. Medicine Biol. 60(2):537–548.Crossref, Google Scholar
- (2009) Robust Optimization. Princeton Series in Applied Mathematics (Princeton University Press, Princeton, NJ).Crossref, Google Scholar
- (2008) Computing robust basestock levels. Discrete Optim. 5(2):389–414.Crossref, Google Scholar
- (2013) Probabilistic objective functions for margin-less IMRT planning. Phys. Medicine Biol. 58(11):3563–3580.Crossref, Google Scholar
- (2008) Robust management of motion uncertainty in intensity-modulated radiation therapy. Oper. Res. 56(6):1461–1473.Link, Google Scholar
- (2006) A robust approach to IMRT optimization. Phys. Medicine Biol. 51(10):2567–2583.Crossref, Google Scholar
- (2011) Including robustness in multi-criteria opimization for intensity modulated proton therapy. Phys. Medicine Biol. 57(3):591–608.Crossref, Google Scholar
- (2005) Robust optimization for intensity modulated radiation therapy treatment planning under uncertainty. Phys. Medicine Biol. 50(23):5463–5477.Crossref, Google Scholar
- (2014) Dose optimization in high-dose-rate brachytherapy: A literature review of quantitative models from 1990–2010. Oper. Res. Health Care 3(2):80–90.Crossref, Google Scholar
- (2012) Prostate post-implant dosimetry: Interobserver variability in seed localisation, contouring and fusion. Radiotherapy Oncology 104(2):192–198.Crossref, Google Scholar
- (2016) High-dose-rate prostate brachytherapy inverse planning on dose-volume criteria by simulated annealing. Phys. Medicine Biol. 61(3):1155–1170.Crossref, Google Scholar
- (2012) A characterization of robust radiation therapy treatment planning methods—From expected value to worst case optimization. Medical Phys. 39(8):5169–5181.Crossref, Google Scholar
- (2013) Robust optimization of radiation therapy accounting for geometric uncertainty. Unpublished doctoral dissertation, KTH Engineering Sciences, Stockholm, Sweden.Google Scholar
- (2014) A critical evaluation of worst case optimization methods for robust intensity-modulated proton therapy planning. Medical Phys. 41(8):081701.Crossref, Google Scholar
- (2011) Minimax optimization for handling range and setup uncertainties in proton therapy. Medical Phys. 38(3):1672–1684.Crossref, Google Scholar
- (2013) Mixed integer programming improves comprehensibility and plan quality in inverse optimization of prostate HDR brachytherapy. Phys. Medicine Biol. 58(4):1041–1057.Crossref, Google Scholar
- (2006) A dosimetric study on the Ir-192 high dose rate Flexisource. Medical Phys. 33(12):4578–4582.Crossref, Google Scholar
- (2013) A linear programming model for optimizing HDR brachytherapy dose distributions with respect to the mean dose in the DVH-tail. Medical Phys. 40(8):081705.Crossref, Google Scholar
- (2007) High dose rate brachytherapy in combination with external beam radiotherapy in the radical treatment of prostate cancer: Initial results of a randomised phase three trial. Radiotherapy Oncology 84(2):114–120.Crossref, Google Scholar
- (2013) GEC/ESTRO recommendations on high dose rate afterloading brachytherapy for localised prostate cancer: An update. Radiotherapy Oncology 107(3):325–332.Crossref, Google Scholar
- International Commission on Radiation Units and Measurements (1999) ICRU 62. Prescribing, Recording and Reporting Photon Beam Therapy (Oxford University Press, Oxford, UK).Google Scholar
- (2014) Review of clinical brachytherapy uncertainties: Analysis guidelines of GEC-ESTRO and the AAPM. Radiotherapy Oncology 110(1):199–212.Crossref, Google Scholar
- (2001) Inverse planning anatomy-based dose optimization for HDR-brachytherapy of the prostate using fast simulated annealing algorithm and dedicated objective function. Medical Phys. 28(5):773–779.Crossref, Google Scholar
- (2012) Robust optimization of intensity modulated proton therapy. Medical Phys. 39(2):1079–1091.Crossref, Google Scholar
- (1995) Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM radiation therapy committee task group no. 43. Medical Phys. 22(2):209–234.Crossref, Google Scholar
- (2006) Efficient schemes for robust IMRT treatment planning. Phys. Medicine Biol. 51(21):5621–5642.Crossref, Google Scholar
- (2016) The nutritious supply chain: Optimizing humanitarian food aid. CentER Discussion Paper, Center for Economic Research, Tilburg University, Tilburg, Netherlands.Google Scholar
- (2018) Adjustable robust strategies for flood protection. Omega 82(January):142–154.Google Scholar
- (2017) Dosimetric impact of contouring and needle reconstruction uncertainties in US-, CT- and MRI-based high-dose-rate prostate brachytherapy treatment planning. Radiotherapy 123(1):125–132.Crossref, Google Scholar
- (2011) IPIP: A new approach to inverse planning for HDR brachytherapy by directly optimizing dosimetric indices. Medical Phys. 38(7):4045–4051.Crossref, Google Scholar
- (2007) Prostate volume contouring: A 3D analysis of segmentation using 3DTRUS, CT and MR. Internat. J. Radiation Oncology 67(4):1238–1247.Crossref, Google Scholar
- (2010) PTV margins should not be used to compensate for uncertainties in 3D image guided intracavitary brachytherapy. Radiotherapy Oncology 97(3):495–500.Crossref, Google Scholar
- (2004) Inclusion of organ movements in IMRT treatment planning via inverse planning based on probability distributions. Phys. Medicine Biol. 49(17):4005–4029.Crossref, Google Scholar
- (2004) Errors and margins in radiotherapy. Seminars Radiation Oncology 14(1):52–64.Crossref, Google Scholar
- (2002) Inclusion of geometric uncertainties in treatment plan evaluation. Internat. J. Radiation Oncology Biol. Phys. 52(5):1407–1422.Crossref, Google Scholar
- (2005) Interobserver delineation variation using CT versus combined CT + MRI in intensity-modulated radiotherapy for prostate cancer. Strahlentherapie Onkologie 181(7):424–430.Crossref, Google Scholar
- (2003) The impact of gross tumor volume (GTV) and clinical target volume (CTV) definition on the total accuracy in radiotherapy theoretical aspects and practical experiences. Strahlentherapie Onkologie 179(1):21–30.Crossref, Google Scholar
- (2012) American brachytherapy society consensus guidelines for high-dose-rate prostate brachytherapy. Brachytherapy 11(1):20–32.Crossref, Google Scholar